the mbc 41 series of ultra - low open frame medical power supplies feature a wide universal ac input range of 85 v C 264 vac, offering output power 4 0 w w ith natural convection cooling . they are available in a variety of isolated single output voltages. the m bc41 ultra low profile series is also available in a pcb mount format, facilitating simple embedded integration onto users main pcb assembly . the mbc s eries is desig ned and approved to the latest m edical s tandards (en/iec 60601 - 1), providing 2 x mopp isolatio n for c lass i & class ii applications. these power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications. ? 3 x 2 x 0.75 inches form factor ? pcb mount option available ? 40 watts convection ? approved to en/iec 60601 - 1 ? efficiencies 85% typical ? - 40 to 70 degree operating temperature ? dual fusing ? 2 m illion h ours, telcordia - sr332 - issue 3 mtbf ? standby power < 0.3 w ? medical (bf) safety approvals ? diagnostic ? drug pump ? monitoring ? dialysis ? home health care ? portable equipment
2 m bc 41 series tech.support@psbel.com mbc41 - 1t05l screw terminal 5 v 5 a 0.0 a 1.5% mbc41 - 1005l header mbc41 - 1005p pcb mount mbc41 - 1t12l screw terminal 12 v 3.33 a 0.0 a 1 % mbc41 - 1012l header mbc41 - 1012p pcb mount mbc41 - 1t15 l screw terminal 15 v 2.67 a 0.0 a 1 % mbc41 - 1015l header mbc41 - 1015p pcb mount mbc41 - 1t 24 l screw terminal 24 v 1.67 a 0.0 a 1% mbc41 - 10 24 l header mbc41 - 1024p pcb mount mbc41 - 1t 30 l screw terminal 30 v 1.33 a 0.0 a 1% mbc41 - 10 30 l header mbc41 - 1030p pcb mount mbc41 - 1t48l screw terminal 48 v 0.83 a 0.0 a 1% mbc41 - 1048l header mbc41 - 1048p pcb mount mbc41 - 1t 58 l screw terminal 58 v 0.69 a 0.0 a 1% mbc41 - 1058l header mbc41 - 1058p pcb mount cover - 41 - xbc 3 metal cover kit accessory specifications are for nominal input voltage, 25c unless otherwise stated. input voltage universal 8 5 - 264 vac / 390 vdc input frequency 47 - 63 hz input current 115 vac: 230 vac : 0.8 a max. 0.4 a max. no load power typical < 0. 3 w inrush current 115 vac: 230 vac: 264 vac: 25 a 45 a 75 a leakage current typical (n.a. for class ii option - without input earth pin ) touch current 3 00 a a < 1 00 a switching frequency typical 6 5 k hz 1 for class ii option (without input earth pin) add su ffix: - 2 (e.g.: mbc41 - 1012l - 2). 2 ripple is peak to peak with 20 mhz bandwidth and 10 f (tantalum capacitor) in parallel with a 0.1 f capacitor at rated line voltage and load ranges. output ripple can be more than 10% of the output voltage. 3 when used in cover kit, de - rate output power to 70 % under all operating conditions. cover kit is not suited for pcb mount v ersion.
m bc 41 series 3 asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 408 785 5200 ? 2017 bel power solutions & protection bcd.00 892 _ a b output power c onv ection cooling 4 0 w efficiency typical 8 5 % hold - up time 230 vac : 6 ms line regulation +/ - 0.5% load regulation +/ - 1% transient response 25% step load change, at 0.1 a/ s slew rate, 50% duty cycle, 50 hz = 4% recovery time < 5 ms rise time typical 5 0 ms set point tolerance 2% (3% for 5 v model) over current protection > 110% over voltage protection 110 to 140% short circuit protection hiccup mode operating temperature s tartup is guaranteed with spec . deviation , see fig. 1 - 40 to +70c - 40 to 0c storage temperature - 40 to +85c relative humidity non - condensing 5% to 95% altitude operating: non - operating: 16,000 ft 40,000 ft. mtbf telcordia - sr332 - issue 3 2 million h ours conducted emissions en 55011 - b, cispr22 - b, fcc part15 - b pass radiated emissions en 55011 a; with external core (king core k5b rc 25x12x15 - m in input cable) pass level b input current harmonics en 61000 - 3 - 2 class d voltage fluctuation and flicker en 61000 - 3 - 3 pass esd immunity en 61000 - 4 - 2 level 4, criterion a radiated field immunity en 61000 - 4 - 3 level 3, criterion a electrical fast transient immunity en 61000 - 4 - 4 level 3, criterion a surge immunity en 61000 - 4 - 5 level 3, criterion a conducted immunity en 61000 - 4 - 6 level 3, criterion a magnetic field immunity en 61000 - 4 - 8 level 4, criterion a voltage dips, interruptions en 61000 - 4 - 11 criterion a & b
4 m bc 41 series tech.support@psbel.com isolation voltage input to output: ( medical applications ) input to gnd: (not applicable for class ii option) output to gnd: for type bf for type b (n/a f or class ii option) 4 000 vac 1500 vac 1500 vac 500 vac safety standard(s) approved to the latest edition of the following standards: csa/ul60601 - 1, en60601 - 1 and iec60601 - 1. agency approvals nemko, ul, c - ul ce mark complies with lvd directive ac input connector j1 screw terminal / header pin 1 pin 2 pin 3 ac line not fitted ac neutral tyco: 640445 - 3 mating: 647402 - 3; pins: 3 - 647409 - 1 (header) dc output connector j2 screw terminal / header pin 1 , 2 pin 3, 4 v 1 + ve v1 - ve tyco: 640445 - 4 mating: 647402 - 4; pins: 3 - 647409 - 1 weight approx. 1 00 g dimensions 76.2 x 50.8 x 19.05 mm ( 3 x 2 x 0.75 inches ) figure 1. derating curve for all outputs de - rate linearly from 100% at 50c to 50% at 70c %
m bc 41 series 5 asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 408 785 5200 ? 2017 bel power solutions & protection bcd.00 892 _ a b mechanical drawing C option s with header and screw terminal mechanical drawing C pcb mount option notes: in case the pcb is mounted in a metal enclosure, using metal hardware ensure the following: 1 stand off, used to mount pcb has od of 5.4 mm max. 2 screws, used to fix pcb on stand off, have head dia of 6.0 mm max. 3 washer, if used, to have dia of 6.5 mm max. nuclear and medical applications - products are not designed or intended for use as critical components in life support systems, equipmen t used in hazardous environments, or nuclear control systems. technical revisions - the appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. specifications are subject to change without notice.
|